
Latex Examination Gloves Powder-Free
Natural cream-colored latex examination gloves, powder-free with polymer donning coating. AQL 1.5 medical-grade, EN 455 certified. Superior tactile sensitivity and 700% elongation for clinical use. 100 pcs per box.
Highlights
- Natural rubber latex delivers superior tactile sensitivity for IV insertion, palpation, and fine motor clinical procedures — second-skin conformity that synthetic alternatives cannot match
- ≥700% elongation before failure — conforms precisely to hand movements without resistance, reducing hand fatigue during extended wear
- Polymer inner coating replaces cornstarch powder — eliminates airborne allergens, wound contamination, and post-use hand drying
- Natural latex molecular structure provides a continuous pathogen barrier meeting EN 455 biological safety requirements
- Most cost-effective medical-grade glove material for high-volume hospital procurement where latex allergy is screened
- EN 455 Parts 1-3 certified, AQL 1.5 medical-grade quality control, CE marked for EU market compliance
Specifications
| Product Name | Latex Examination Gloves Powder-Free Natural |
|---|---|
| Material | Natural Rubber Latex |
| Color | Natural / Cream translucent |
| Thickness | 0.08 mm (palm) |
| Powder Status | Powder-free (polymer coated) |
| Elongation at Break | ≥700% |
| Sizes Available | S, M, L, XL |
| Fit | Ambidextrous |
| Quality Standard | AQL 1.5 |
| Certification | EN 455-1, EN 455-2, EN 455-3 - CE Marked |
| Package | 100 pcs per box |
| Usage Type | Single-use disposable |
Product Detail
Gloves & Hand Protection · Natural Rubber Latex · Powder-Free · EN 455 455
Latex Examination Gloves Powder-Free Natural
Natural rubber latex examination gloves in natural cream colour, engineered for healthcare professionals who prioritize tactile sensitivity and elasticity. Latex remains the gold standard for dexterity - the natural rubber polymer conforms to the hand like a second skin, delivering tactile feedback that synthetic alternatives cannot fully replicate. The powder-free formulation uses a polymer inner coating for smooth donning without cornstarch. AQL 1.5 medical-grade quality control. EN 455 certified. Ambidextrous fit. Supplied 100 pcs per box.
What Sets It Apart
Six reasons clinicians specify natural latex
Superior Tactile Sensitivity
Natural rubber latex delivers unmatched tactile feedback. For procedures requiring fine motor control - IV insertion, palpation, microsurgery assistance - the difference between latex and synthetic is immediately perceptible to experienced clinicians.
Second-skin feel
Exceptional Elasticity
Natural latex stretches up to 700% before failure - far beyond nitrile or vinyl. This elasticity means the glove conforms precisely to hand movements without resistance, reducing hand fatigue during extended wear.
700% elongation
Powder-Free Polymer Coating
The inner surface is coated with a polymer donning layer that replaces cornstarch powder. Eliminates powder-related wound contamination, airborne allergens, and post-use hand drying.
No powder · Polymer donning
Natural Barrier Properties
Natural rubber latex provides excellent resistance to bloodborne pathogens and biological fluids. The molecular structure creates a continuous barrier meeting EN 455 requirements.
Pathogen barrier
Cost-Effective at Volume
Latex gloves remain the most cost-effective medical-grade glove material for high-volume clinical procurement. For facilities without latex-allergic staff, the per-unit cost advantage over nitrile is significant at container-load volumes.
Lowest cost-per-glove
EN 455 Certified · CE Marked
Certified to EN 455 Parts 1-3. AQL 1.5 medical-grade quality control. CE marked for EU market compliance. Full test reports and declaration of conformity available.
CE · EN 455
Specifications
Parameter | Value |
|---|---|
Product Name | Latex Examination Gloves Powder-Free Natural |
Material | Natural Rubber Latex |
Color | Natural / Cream translucent |
Thickness | 0.08 mm (palm) |
Powder | Powder-free (polymer coated) |
Sizes | S, M, L, XL |
Fit | Ambidextrous |
Quality Standard | AQL 1.5 |
Certification | EN 455-1, EN 455-2, EN 455-3 - CE Marked |
Package | 100 pcs per box |
Elongation | ≥700% before failure |
Usage Type | Single-use disposable |
Application Scenarios
General Patient Examination
Routine clinical examination where tactile sensitivity is essential and latex allergy has been screened out.
Diagnostic Procedures
Palpation and physical assessment where the clinician needs maximum fingertip sensitivity through the glove.
Laboratory Work
Sample handling and bench work requiring fine dexterity. Latex elasticity reduces hand strain during long sessions.
High-Volume Procurement
Cost-effective bulk supply for hospital networks where latex-allergic staff protocols are in place.
Procurement Note
Latex gloves require a latex-allergy screening protocol for all staff who will use them. For facilities with mixed or unknown allergy status, consider nitrile as the default and latex as a specified option for clinicians who prefer it. Both glove types should be available in the PPE catalog. MOQ, carton quantities, and OEM packaging available upon request.
Certifications & Manufacturerurer
Certified to EN 455 Parts 1-3 with CE marking. AQL 1.5 quality standard. Manufactured by Justsun (Xiamen Jiasheng Group), established 1997, specialising in CE/FDA-certified disposable medical supplies. Facility: 26,100+ m2, 400+ employees. Declaration of conformity and test reports available upon request.
CE MarkedEN 455 Parts 1-3AQL 1.5Since 1997
Frequently Asked Questions
Why choose latex over nitrile?
Latex offers superior tactile sensitivity, elasticity, and comfort compared to nitrile. It is the preferred material for clinicians performing procedures requiring fine touch. However, latex contains natural rubber proteins that can cause Type I allergic reactions in sensitized individuals. Choose latex when allergy screening is in place and tactile performance is the priority.
What does powder-free mean?
Powder-free gloves use a polymer inner coating instead of cornstarch powder for donning. This eliminates airborne powder particles that can contaminate sterile fields, interfere with wound healing, and cause respiratory irritation in sensitized individuals.
What is AQL 1.5?
AQL (Acceptable Quality Limit) measures the maximum defect rate per inspection lot. AQL 1.5 allows less than or equal to 1.5% defects - the medical-grade threshold for examination gloves. This is tighter than AQL 2.5 used for standard vinyl gloves.
What documentation is provided?
Each shipment includes the EN 455 test report, CE declaration of conformity, and packing list. Batch-specific certificates available on request.
Request a Quote for Latex Gloves
Get factory-direct pricing, EN 455 documentation, and delivery timelines for your procurement volume.




